ishrith-gowda/SA-CycleGAN-2.5D
SA-CycleGAN-2.5D: Self-Attention CycleGAN with Tri-Planar Context for Multi-Site MRI Harmonization
   
Authors: Ishrith Gowda (UC Berkeley EECS), Chunwei Liu (Purdue University)
Paper: SA-CycleGAN-2.5D: Self-Attention CycleGAN with Tri-Planar Context for Multi-Site MRI Harmonization
overview
multi-site neuroimaging analysis is fundamentally confounded by scanner-induced covariate shifts, where the marginal distribution of voxel intensities P(x) varies non-linearly across acquisition protocols while the conditional anatomy P(y|x) remains constant. this is particularly detrimental to radiomic reproducibility, where acquisition variance often exceeds biological pathology variance.
SA-CycleGAN-2.5D is a domain adaptation framework that reduces Maximum Mean Discrepancy (MMD) by 99.1% (1.729 → 0.015) across two institutional MRI domains (BraTS and UPenn-GBM) without paired training data, collapsing a trained scanner domain classifier to near-chance accuracy (59.7%).
key results
architecture
SA-CycleGAN-2.5D integrates three architectural innovations:
1. 2.5D tri-planar manifold injection
- input: 12-channel volume (3 adjacent axial slices × 4 MRI modalities: T1, T1ce, T2, FLAIR)
- preserves through-plane gradients ∇z at O(HW) complexity, bridging 2D efficiency and 3D spatial consistency
- eliminates the slice-discontinuity artifacts common in 2D-only harmonization approaches
2. U-ResNet generator with dense voxel-to-voxel self-attention
- surpasses the O(√L) receptive field limit of standard CNNs
- models global scanner field biases — critical for field-strength-induced intensity shifts
- CBAM (Convolutional Block Attention Module) applied at resolution layers [3, 4, 5]
- 9 residual blocks, ngf=64
3. spectrally-normalized discriminator
- constrains Lipschitz constant K_D ≤ 1 for stable adversarial optimization
- prevents mode collapse without gradient penalty overhead
journal extension contributions (5 novel modules)
intended use
intended uses:
- multi-site MRI harmonization for clinical/research neuroimaging pipelines
- pre-processing step before radiomic feature extraction, segmentation, or classification
- privacy-preserving harmonization via the federated variant (no raw data sharing)
- bandwidth-constrained deployment via the compression variant
out-of-scope uses:
- modalities other than brain MRI (not validated)
- clinical diagnosis (research use only)
- sites with fewer than ~50 subjects per scanner type (insufficient domain coverage)
training details
usage
import torch
from neuroscope.models.generator import UResNetGenerator
from neuroscope.models.cyclegan import SACycleGAN25D
# load model
model = SACycleGAN25D.from_pretrained("ishrith-gowda/SA-CycleGAN-2.5D")
model.eval()
# input: [B, 12, H, W] — 3 adjacent axial slices × 4 modalities (T1, T1ce, T2, FLAIR)
# normalized to [-1, 1] per modality
input_25d = torch.randn(1, 12, 128, 128) # replace with real volume
with torch.no_grad():
harmonized = model.generator_A2B(input_25d) # [B, 4, H, W] — center slice, all modalitiessee the official repository for full preprocessing pipeline, dataset loading, and inference scripts.
data
trained on:
- [BraTS-TCGA-GBM](https://www.cancerimagingarchive.net/collection/tcga-gbm/) — The Cancer Imaging Archive, multi-institutional glioblastoma cohort
- [UPenn-GBM](https://www.cancerimagingarchive.net/collection/upenn-gbm/) — University of Pennsylvania GBM cohort (multiple scanner configurations)
see `ishrith-gowda/MRI-Harmonization-BraTS-UPenn` for the preprocessed dataset card.
ethical considerations
- data privacy: all training data is de-identified per TCIA data use agreements
- federated variant: enables cross-site harmonization with zero raw data transfer, directly addressing patient privacy in multi-institutional settings
- clinical use: this is a research tool. outputs should not be used for clinical diagnosis without further validation
- bias: evaluated exclusively on adult glioma patients. performance on pediatric, non-glioma, or non-brain MRI is unknown
citation
@article{gowda2026sacyclegan25d,
title={SA-CycleGAN-2.5D: Self-Attention CycleGAN with Tri-Planar Context for Multi-Site MRI Harmonization},
author={Gowda, Ishrith and Liu, Chunwei},
journal={arXiv preprint arXiv:2603.17219},
year={2026},
url={https://arxiv.org/abs/2603.17219},
doi={10.48550/arXiv.2603.17219}
}acknowledgments
data provided by The Cancer Imaging Archive (TCIA) under the BraTS-TCGA-GBM and UPenn-GBM collections. compute provided by Chameleon Cloud (NSF-funded research infrastructure). research conducted under the supervision of Dr. Chunwei Liu.