CoolFace
Datasetpublic

tasksource/reqeval-ambiguity-detection

sourceHugging Faceupdated 3y agoView on Hugging Face
1likes12downloads
train.tsv141 linesDownload Raw Back to root
1	ID	Sentence	Detected as21	library#01	All material that is stored in the repository will enter <referential>it</referential> via the Ingest function.	NOCUOUS32	library#02-1	The Library may want to accept important digital materials in non-standard formats in case <referential>we</referential> are able to migrate them to a more usable format in the future.	NOCUOUS43	library#02-2	The Library may want to accept important digital materials in non-standard formats in case we are able to migrate <referential>them</referential> to a more usable format in the future.	INNOCUOUS54	library#03	Once material has arrived, <referential>it</referential> must undergo several reviews, including virus checking, format compliance and anticipated content and file type.	INNOCUOUS65	library#04	Allows resources to be reviewed before a decision is made whether <referential>they</referential> should be retained.	INNOCUOUS76	library#05	Allows metadata to be stored in a database in a manner that conforms to repository reformatting and linked to <referential>their</referential> corresponding objects via an identifier.	INNOCUOUS87	library#06	The Coordinate Updates function also incorporates the storage identification information into the Descriptive Information for the AIP and transfers <referential>it</referential> to the Data Management entity along with a database update request.	NOCUOUS98	library#07	Archival Storage functions include receiving AIPs from Ingest and adding <referential>them</referential> to permanent storage, managing the storage hierarchy, refreshing the media on which archive holdings are stored, performing routine and special error checking, providing disaster recovery capabilities, and providing AIPs to Access to fulfill orders.	INNOCUOUS109	library#08	<referential>It</referential> will also conform to any special levels of service required for the AIP, or any special security measures that are required, and ensures the appropriate level of protection for the AIP.	NOCUOUS1110	library#09	<referential>It</referential> monitors error logs to ensure AIPs are not corrupted during transfers.	NOCUOUS1211	library#10	However, the data constituting the Packaging Information may be changed as long as <referential>it</referential> continues to perform the same function and there is a straightforward implementation that does not cause information loss.	NOCUOUS1312	library#11	The migration strategy must select a storage medium, taking into consideration the expected and actual rates of errors encountered in various media types, <referential>their</referential> performance, and <referential>their</referential> costs of ownership.	INNOCUOUS1413	library#12	This function receives an AIP request that identifies the requested AIP(s) and provides <referential>them</referential> on the requested media type or transfers <referential>them</referential> to a staging area.	INNOCUOUS1514	library#13	The Generate Report function receives a report request from Ingest, Access or Administration and executes any queries or other processes necessary to generate the report that <referential>it</referential> supplies to the requester.	NOCUOUS1615	library#14	<referential>It</referential> may also receive a report request from Access and provides descriptive information for a specific AIP.	NOCUOUS1716	library#15	Administration functions include soliciting and negotiating submission agreements with producers, auditing submissions to ensure that <referential>they</referential> meet archive standards, and maintaining configuration management of system hardware and software.	NOCUOUS1817	library#16	Audits data in SIPs or AIPs to ensure that <referential>they</referential> meet specified requirements.	NOCUOUS1918	library#17	The Activate Requests function maintains a record of event-driven requests and periodically compares <referential>it</referential> to the contents of the archive to determine if all needed data is available.	NOCUOUS2019	library#18	Maintains a record of event-driven events and compares <referential>it</referential> to the contents of the repository.	INNOCUOUS2120	library#19	The Monitor Designated Community function interacts with archive Consumers and Producers to track changes in <referential>their</referential> service requirements and available product technologies.	INNOCUOUS2221	library#20	Interacts with repository users and content providers to track changes in <referential>their</referential> service requirements and available product technologies.	NOCUOUS2322	library#21	This function receives reports from the Monitor Designated Communities and Monitor Technology functions, and <referential>it</referential> receives performance information, inventory reports and summarized consumer comments from Administration.	INNOCUOUS2423	library#22	This function also receives external data standards from Monitor Technology and produces profiles of those standards that are sent to Administration as proposals on <referential>their</referential> potential usage.	NOCUOUS2524	library#23	Produces profiles of those standards that are sent to Administration as proposals on <referential>their</referential> potential usage.	NOCUOUS2625	library#24	The NLM will test preservation actions in order to determine <referential>their</referential> effectiveness across a range of digital objects.	NOCUOUS2726	library#25	The NLM System Administration/Programming Access, ultimate rights to the system, required for <referential>its</referential> management, development, and for assigning appropriate rights to users.	NOCUOUS2827	weather#01	The Clarus system shall process data as <referential>they</referential> are received.	INNOCUOUS2928	weather#02	The Clarus system shall be able to base <referential>its</referential> quality control process on values from multiple observations.	INNOCUOUS3029	weather#03	The Clarus system shall be able to communicate with RWIS databases through <referential>their</referential> native interfaces.	INNOCUOUS3130	weather#04	The Clarus system shall be able to collect data from sources within 5 minutes of <referential>them</referential> becoming available.	NOCUOUS3231	weather#05	The CAS shall be configurable to allow new observation types to be implemented as <referential>they</referential> become available.	INNOCUOUS3332	weather#06	The CS shall collect environmental data based on <referential>its</referential> configured schedule.	NOCUOUS3433	weather#07	The CS shall be able to dynamically adjust <referential>its</referential> retrieval schedules when environmental data is expected to be ready but is temporarily delayed.	INNOCUOUS3534	weather#08	The CS shall process environmental data as <referential>they</referential> are received.	INNOCUOUS3635	weather#09	The Clarus system shall be able to communicate with environmental sensor stations through <referential>its</referential> collector using the NTCIP ESS 1204.	NOCUOUS3736	weather#10	The CS shall be able to accept data from an RWIS database in <referential>its</referential> native output format.	NOCUOUS3837	weather#11	The Clarus system shall be able to communicate with an individual ESS through <referential>its</referential> native interface.	NOCUOUS3938	weather#12	The DOG shall be able to monitor new environmental data services as <referential>they</referential> are added.	INNOCUOUS4039	weather#13	The DOG shall be able to record <referential>its</referential> activities.	INNOCUOUS4140	weather#14	The QEDC shall maintain observations and <referential>their</referential> associated quality flags for seven days.	INNOCUOUS4241	weather#15	The QEDC shall support queries for <referential>its</referential> observations.	INNOCUOUS4342	weather#16	The QEDS shall log <referential>their</referential> activities.	NOCUOUS4443	weather#17	The QChS shall be able to base <referential>its</referential> quality checking process on values distributed in time.	INNOCUOUS4544	weather#18	The contributors shall define the units of measurements of <referential>their</referential> shared data and information.	INNOCUOUS4645	weather#19	The Clarus program shall determine how <referential>it</referential> will provide data and information to contributors.	INNOCUOUS4746	weather#20	"""The Clarus program shall inform contributors of the acceptance and use"""" of <referential>their</referential> data and information."""""""	INNOCUOUS4847	railway#01	The logon screen shall activate command control for the user if the user requests <referential>it</referential> and has authorization.	INNOCUOUS4948	railway#02	When a device status has been overridden, on the screen <referential>it</referential> shall appear with different color from the normal and alarm status colors.	INNOCUOUS5049	railway#03	<referential>It</referential> shall display and allow modification of all database tables with the exception of log tables.	NOCUOUS5150	railway#04	The user should not be able to update log entries other than for <referential>their</referential> own login, for the current day and current shift.	NOCUOUS5251	railway#05	Any change in device state shall be reported on the screen not later than 2 seconds from the time <referential>it</referential> occurs.	INNOCUOUS5352	railway#06-1	When each workstation and control unit (workstation or intelligent controller at the FCU or DCU) comes online, the system shall identify <referential>it</referential> and all its associated device sensors.	NOCUOUS5453	railway#06-2	When each workstation and control unit (workstation or intelligent controller at the FCU or DCU) comes online, the system shall identify it and all <referential>its</referential> associated device sensors.	NOCUOUS5554	railway#07	The RLCS software shall initialize each control unit and device sensor as <referential>it</referential> is identified.	NOCUOUS5655	railway#08	The devices can be manually controlled/operated from <referential>their</referential> cabinets (e.g.: Gates).	INNOCUOUS5756	railway#09	The normal operating mode is Monday through Friday, between 5:00am and 8:00pm, but the system must be functional in order to stay in <referential>its</referential> closed state after hours.	INNOCUOUS5857	railway#10	The ETCS shall provide the driver with information to allow <referential>him</referential> to drive the train safely.	INNOCUOUS5958	railway#11-1	If the supervision is performed by a RBC <referential>it</referential> shall be possible to prevent movements of a traction unit in its area if not authorised by the RBC.	NOCUOUS6059	railway#11-2	If the supervision is performed by a RBC it shall be possible to prevent movements of a traction unit in <referential>its</referential> area if not authorised by the RBC.	NOCUOUS6160	railway#12	<referential>It</referential> shall be possible to implement one or more of the ETCS application levels on a line.	INNOCUOUS6261	railway#13	The ETCS shall be compatible with existing national systems listed in the CCS TSI such that <referential>it</referential> does not interfere with the national systems and is not interfered with by the national systems.	INNOCUOUS6362	railway#14	If an ETCS equipped train passes a level transition to a line fitted with more than one level, the onboard shall switch to the highest level, according to the priority given by trackside, for which <referential>it</referential> is equipped.	INNOCUOUS6463	railway#15	On request of the RBC, the driver shall have the possibility to confirm that the track ahead of <referential>him</referential> until the end of the on sight section is clear .	INNOCUOUS6564	railway#16	The braking curves shall ensure that the train complies with <referential>its</referential> speed requirements.	INNOCUOUS6665	railway#17	If the release speed is calculated on board <referential>it</referential> shall ensure that the train will stop before reaching the danger point .	NOCUOUS6766	railway#18	A train shall be supervised to <referential>its</referential> static and dynamic train speed profiles.	INNOCUOUS6867	railway#19	Within the braking curve area, a warning shall be given to the driver to enable <referential>him</referential> to react and avoid intervention from ETCS equipment at least 5 sec. before the intervention.	INNOCUOUS6968	railway#20	The ETCS trainborne equipment shall transmit <referential>its</referential> own train identification to the RBC.	INNOCUOUS7069	railway#21	If a train cannot stop at the proposed new target location <referential>it</referential> shall reject the request and keep the old target location.	NOCUOUS7170	railway#22	The train may proceed unrestricted to the end of <referential>its</referential> movement authority.	INNOCUOUS7271	railway#23	<referential>It</referential> is acceptable that only one mobile user involved in the group call may talk at any time.	INNOCUOUS7372	railway#24	If the text message facility is implemented, <referential>it</referential> shall not interfere with the ability of users to make or receive high priority voice or data calls.	INNOCUOUS7473	railway#25	Where fax functionality is provided, <referential>it</referential> shall be possible to interrupt the fax to make or receive a high priority voice or data call.	NOCUOUS7574	railway#26	The network shall provide the ability to inform a user, who is involved in an existing call, of attempts by other users to contact <referential>them</referential>.	NOCUOUS7675	railway#27	Where network services are chargeable, <referential>it</referential> should be possible for the network to provide information about call rates and on-going call charges.	INNOCUOUS7776	railway#28	Picking up the handset shall transfer the communication to the handset and reduce the loudspeaker volume to <referential>its</referential> minimum level.	NOCUOUS7877	railway#29	An indication shall be provided to the driver as a reminder of the need to use the Push-To-Talk button on the handset if <referential>he</referential> wants to talk.	INNOCUOUS7978	railway#30	<referential>It</referential> shall be possible for a driver to initiate Railway emergency calls (see section 13).	INNOCUOUS8079	railway#31	If the train moves out of the call area whilst the call is in progress, <referential>it</referential> will leave the call and an audible and visual indication of the loss of call shall be provided to the driver.	NOCUOUS8180	railway#32	Once the driver has accepted the standard point-to-point call, <referential>it</referential> shall be connected appropriately, eg if the driver has accepted the call by lifting the handset, then the call shall be routed to the handset.	INNOCUOUS8281	railway#33	In this case, the security device alerts the driver if the link has failed or if <referential>it</referential> is cancelled.	NOCUOUS8382	railway#34-1	<referential>It</referential> should be possible for the Cab radio to be used without the network service (if it should fail or if there is no authorised network coverage), such that local open channel communications are still possible.	NOCUOUS8483	railway#34-2	It should be possible for the Cab radio to be used without the network service (if <referential>it</referential> should fail or if there is no authorised network coverage), such that local open channel communications are still possible.	NOCUOUS8584	railway#35	Where the Cab radio is required by a national railway to support a handheld portable, the Cab radio shall: - provide a clear indication as to whether the handheld portable is activated or not; - provide an interface to allow the handheld portable to be recharged when not in use; - forward calls automatically to the handheld portable when the handheld portable is activated; - cancel any call forwarding to the handheld portable when <referential>it</referential> is deactivated; - allow the driver to override the call forwarding to the handheld portable.	INNOCUOUS8685	railway#36	When the MMI is switched on, the configuration shall be determined by the time elapsed since the MMI was last switched off: - less than t minutes – the MMI shall power up with the same configuration as when <referential>it</referential> was last powered down; - greater than t minutes – the MMI shall power up with default settings.	INNOCUOUS8786	railway#37	If directed network selection is implemented, input from the external device(s) shall initiate the network change regardless of the identity of the current network and how <referential>it</referential> was selected.	NOCUOUS8887	railway#38	Non leading drivers shall be able to indicate to the system <referential>their</referential> location in the train during the registration procedure (2nd driver, 3rd driver etc).	INNOCUOUS8988	railway#39	Each type of equipment has slightly different requirements placed upon <referential>it</referential> in terms of EMC and climate.	INNOCUOUS9089	railway#40	The design of the equipment shall make <referential>it</referential> possible to install <referential>it</referential> within a cab complying with the requirements of UIC fiche 651 concerning the layout of cab equipment5.	NOCUOUS9190	railway#41	If the call is a broadcast call, the user shall be informed that <referential>he</referential> cannot speak as part of the broadcast call.	INNOCUOUS9291	railway#42	Where a change of functional number is required, <referential>it</referential> shall be possible for the user to initiate the change.	NOCUOUS9392	railway#43-1	<referential>It</referential> shall be possible for the user to find and display stored numbers and their information.	NOCUOUS9493	railway#43-2	It shall be possible for the user to find and display stored numbers and <referential>their</referential> information.	NOCUOUS9594	railway#44	The Operational radio is specified to allow <referential>its</referential> use in the operating environment experienced on the operational railway (eg shunting and maintenance).	INNOCUOUS9695	railway#45	Controls shall be designed such that <referential>they</referential> are suitable for use by people wearing gloves.	INNOCUOUS9796	railway#46-1	<referential>It</referential> should be possible for the system to prevent certain types of users from registering functional numbers that they are not authorised to use, for example: - train number; - driver of train; - shunting team leader.	NOCUOUS9897	railway#46-2	It should be possible for the system to prevent certain types of users from registering functional numbers that <referential>they</referential> are not authorised to use, for example: - train number; - driver of train; - shunting team leader.	NOCUOUS9998	railway#47	As a minimum, the location information used by the EIRENE system shall be derived from that available from the network <referential>itself</referential> (eg current cell or base station serving the mobile).	NOCUOUS10099	railway#48	After the 30 second period, if the connection was unsuccessful, the system shall provide another audible and visual indication that <referential>it</referential> was unable to connect the call.	INNOCUOUS101100	railway#49	For post-incident analysis, <referential>it</referential> is important that the origination and reception of Railway emergency calls by mobiles is confirmed by a message sent to a ground-based central location (and also recorded in the on-train recording device).	NOCUOUS102101	railway#50	Throughout the duration of the shunting group call, <referential>it</referential> shall be possible for any member of the shunting group to speak to all other members of the group, using the PTT function (as described in sections 5.2.2.53, 6.2.2.12 and 7.2.2.20), except during transmission of the link assurance signal.	NOCUOUS103102	railway#51	The shunting leader can then choose the moment when <referential>he</referential> takes or rejects the call.	INNOCUOUS104103	railway#52	In this case, the safety device will alert the driver only if the link assurance signal has failed or if <referential>it</referential> is cancelled.	INNOCUOUS105104	railway#53	The 300ms represents <referential>our</referential> current best estimate of the QoS figure, although this will need to be confirmed through user trials.	NOCUOUS106105	railway#54	Each authority can decide whether <referential>it</referential> wishes to use synchronised BTSs.	INNOCUOUS107106	railway#55	The network shall terminate the ongoing VGCS/VBS call if <referential>it</referential> receives the 3-digit sequence “***” transmitted via DTMF signals.	NOCUOUS108107	railway#56	The network shall send the SET-PARAMETER message with the attribute “D-ATT = T”1 [EN 301 515, Index [6]] to the mobile station of the talking subscriber if <referential>it</referential> receives the 3- digit sequence “###” transmitted via DTMF or the group call SETUP message2 from a controller terminal.	NOCUOUS109108	railway#57-1	When the network has detected the 3-digit DTMF sequence “###” transmitted via DTMF from a controller terminal and if the controller was not previously talking <referential>it</referential> should indicate its recognition by playing a single DTMF grant tone “#” of duration of 100ms  5ms to be sent to that controller terminal only.	NOCUOUS110109	railway#57-2	When the network has detected the 3-digit DTMF sequence “###” transmitted via DTMF from a controller terminal and if the controller was not previously talking it should indicate <referential>its</referential> recognition by playing a single DTMF grant tone “#” of duration of 100ms  5ms to be sent to that controller terminal only.	NOCUOUS111110	railway#58	The network shall send the SET-PARAMETER message with the attribute “D-ATT = F”3 [EN 301 515, Index [6]] to the mobile of the talking subscriber only if <referential>it</referential> has received the 3-digit sequence “#**” transmitted via DTMF from all the talking controllers4.	NOCUOUS112111	railway#59	Many of the railway specific standards referenced are Pre-standards (eg [prEN 50155, ENV 50121, prEN 50125]) and should be re-examined for <referential>their</referential> applicability to the EIRENE system if any modifications are made to these standards in the future.	INNOCUOUS113112	railway#60	Each of the other cabs on the train will be contacted using <referential>its</referential> functional number (registered by the other drivers prior to the establishment of the call).	NOCUOUS114113	railway#61	Upon registration, the mobile shall be accessible by calling the MSISDN or the Engine or Coach number with which <referential>it</referential> is associated.	INNOCUOUS115114	railway#62	The Cab radio system shall provide a means for the driver to terminate established calls which <referential>he</referential> is authorised to terminate.	INNOCUOUS116115	home#01	The DigitalHome programmable Appliance Manager shall provide for management of a home’s small appliances, including lighting units, by allowing a user to turn <referential>them</referential> on or off as desired.	NOCUOUS117116	home#02	Although the product produced under this document will be a “prototype” version, all modules and components of this prototype version shall be designed and implemented in such a manner that <referential>it</referential> may be incorporated in a fully specified commercial version of the DigitalHome System.	NOCUOUS118117	home#03	The DigitalHome System shall provide users with online documentation about the DigitalHome system installed in <referential>their</referential> home.	INNOCUOUS119118	space#01	The FCP shall, if the NEFU ICP fails to send <referential>its</referential> ICP Ready signal, mask out that ICP, but continue to use the NE.16.	INNOCUOUS120119	space#02	Each rate group has some number of tasks associated with <referential>it</referential>, and <referential>it</referential> also has a rate for those tasks.	INNOCUOUS121120	space#03	The enabled tasks are then unblocked at the rate given in <referential>its</referential> associated rate group.	NOCUOUS122121	space#04-1	An API call is available for the task to call to block <referential>itself</referential> when it is finished with its cyclic processing.	NOCUOUS123122	space#04-2	An API call is available for the task to call to block itself when <referential>it</referential> is finished with its cyclic processing.	NOCUOUS124123	space#04-3	An API call is available for the task to call to block itself when it is finished with <referential>its</referential> cyclic processing.	NOCUOUS125124	space#05	There is up to a full major frame from notification of an impending mode change to acting on <referential>it</referential> in minor frame 0 of the next major frame plus the time <referential>it</referential> takes during the next minor frame 0 to switch tasking.	NOCUOUS126125	space#06	The scheduler shall execute cyclic tasks, providing an API call to allow the application to block until <referential>its</referential> next iteration.	NOCUOUS127126	space#07	The scheduler shall give tasks priority values according to <referential>their</referential> rate - the higher the rate, the higher the priority.	NOCUOUS128127	space#08	The scheduler shall provide a mechanism to inform a task when <referential>it</referential> did not complete during the previous frame and restart <referential>it</referential> at the beginning of the task.	NOCUOUS129128	space#09	All tasks in rate groups and <referential>their</referential> corresponding schedules for all vehicle modes will be setup at system initialization.	NOCUOUS130129	space#10	Tasks in a rate group must suspend on a scheduler API call at the top of <referential>their</referential> execution loop.	INNOCUOUS131130	space#11	For hardware exceptions and reserved exceptions, the FTSS shall make the error type and <referential>its</referential> context data available to the application, then return from the exception handler to the task that was running when the exception occurred.	NOCUOUS132131	space#12	Messages are addressed with a global unique communication identifier that routes <referential>them</referential> to the appropriate virtual group (VG) and socket.	INNOCUOUS133132	space#13	This restriction does NOT apply to the ICPs since <referential>they</referential> are running as simplex VGs.	INNOCUOUS134133	space#14	The FTSS shall mask out a babbling NE or ICP within 40 milliseconds after <referential>it</referential> is detected.	NOCUOUS135134	space#15	Synchronous message passing sockets shall queue outgoing messages until <referential>they</referential> are transmitted at frame boundaries.	NOCUOUS136135	space#16	"""Pipes may be opened by multiple receiving tasks if <referential>they</referential> are created with the broadcast"""" capability; otherwise <referential>they</referential> may only be opened by one receiving task."""""""	NOCUOUS137136	space#17	"""Communication services shall provide the capability to create pipe""""s which """"broadcast"""" <referential>their</referential> messages to all virtual groups."""""""	NOCUOUS138137	space#18	If the broadcast option is used, each virtual group should open the pipe and read from <referential>it</referential> to avoid flow control problems.	NOCUOUS139138	space#19	The application software shall have the capability to reset a permanently failed channel to <referential>its</referential> initial recovery state.	NOCUOUS140139	space#20	Redundancy Management picks up where <referential>it</referential> left off in these attempts.	INNOCUOUS141